Product Detail

PHOTASGARD® DHKF

The PHOTASGARD® DHKF light intensity measuring transducer supports six switchable measuring ranges (six devices in one). The sensor has been designed for installation in suspended ceilings. The connecting head is pluggable for quick and easy mounting. The measuring transducer is accommodated in a separate housing.

The sensor is specifically adapted to the sensitivity of the human eye. Its greatest sensitivity is in the range of 350 nm to 820 nm. With its special filter, the sensor is therefore ideally suited to exposure measuring of daylight and/or to measuring artificial light of high colour temperature (similar to sunlight).

No price
Display
  1. Yes
  2. No
Collect
  • TECHNICAL DETAILS
  • DOWNLOADS
Power consumption
< 1 W at 24 V DC; < 2 VA at 24 V AC
Deviation, humidity
typically < 5 % of final value
Sensor
light sensor
Measuring ranges
multi-range switching (via DIP switches)
with 6 switchable measuring ranges
0...500 Lux/ 1 kLux/ 2 kLux/ 5 kLux/ 20 kLux/ 60 kLux
(other individual ranges optional, e. g. 100 kLux)
Ambient temperature
–30...+70 °C
Electrical connection
2-, or 3-wire connection
0.14 -1.5 mm 2 via terminal screws on circuit board
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing
plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016)
Housing dimensions
72 x 64 x 37,8 mm (Tyr 1)
Cable gland
M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Connecting head
made of plastic, material polycarbonate (PC), colour white,
pluggable, Ø = approx. 35 mm, H = approx. 29 mm
sensor cable
PVC, LiYY, 4 x 0.14 mm2,
KL = approx. 2 m
Mounting (sensor)
inside suspended ceiling,
ceiling cutout Ø = 30 mm,
cover Ø = < 35 mm
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according EN 60 529) Housing tested
TüV SüD, Report No. 713139052
IP 30 (according EN 60 529) Sensor in the built-in state
Standards
CE conformity,
electromagnetic compatibility according to EN 61326,
according to EMC Directive 2014/ 30/ EU


  • Telephone

    • 19836508612
    • 19836508612
Technical Support: 97建站 | Admin Login
×