AERASGARD® KCO2-WPatented quality product (patent no. DE 10 2014 010 719.1) Maintenance-free AERASGARD® KCO2-SD duct air quality measuring transducer with active output, automatic calibration (fixed), in a compact plastic housing with quick-locking screws, for determining the CO2 content of the air (0…2000 ppm/0...5000 ppm). The transmitter converts the measured values into a standard signal of 0-10 V. Maintenance-free AERASGARD® KCO2-W duct air quality measuring transducer with active/switching output, automatic calibration (can be deactivated), in a compact plastic housing with quick-locking screws, optionally with/without display, for determining the CO2 content of the air (0…2000 ppm/0...5000 ppm). The transmitter converts the measured values into a standard signal of 0-10 V or 4...20 mA (switchable). The sensor device is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. The CO2 content is measured using an optical NDIR sensor (non-dispersive infra-red technology). The detection range is calibrated for standard applications such as the monitoring of residential and conference rooms.
![]()
收藏
产品编号 1501-3140-7301-200
Voltage supply 24 V AC/ DC (± 10 %) Power consumption < 1.5 W/ 24 V DC typical; < 2.9 VA/ 24 V AC typical; peak current 200 mA Measuring range, CO2 multi-range switching (selectable via DIP switches) 0...2000 ppm; 0...5000 ppm Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C (whichever is higher) Pressure dependence ± 0,13 %/ mm Hg Sensor, CO2 Gas exchange by diffusion Output, CO2 0 - 10 V / 4...20 mA Warm up time approx. 1 hour Response time approx. 1 minute, minimum flow rate 0.3 m / s (air) Ambient temperature –10...+60 °C Process connection by mounting flange, plastic (included in the scope of delivery) Electrical connection 0.14 - 1.5 mm2 via terminal screws Cable gland M 16 x 1.5, including strain relief, exchangeable, max. inner diameter 10.4 mm Long-term stability < 2 % in 15 years Relay output with potential-free changeover contact (24 V / 1 A), switchpoint adjustable Protection class III (according to EN 60 730) Output 0 -10 V or 4...20 mA, working resistance < 800 Ω (selectable via DIP switches) with offset potentiometer (± 10 % of the measuring range Sensor VOC sensor (metal oxide) (VOC = volatile organic compounds), with manual calibration (via zero button), with automatic calibration (can be deactivated via DIP switches) Protective tube PLEUROFORM, material polyamide (PA6), with torsion protection, Ø 20 mm, NL = 202.5 mm, vmax = 30 m/s (air) Cable connection cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or M12 connector according to DIN EN 61076-2-101 (optional on request) Housing plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced, with quick-locking screws (slotted/ Phillips head - combination), colour traffic white (similar to RAL 9016), housing cover for display is transparent ! Housing dimensions 72 x 64 x 43.3 mm (Tyr 1 with Display) Protection type IP 65 (according to EN 60 529)* Housing tested, TüV SüD, Report No. 713139052 (Tyr 1) Housing in the built-in state (permeable PLEUROFORM: IP 30) Standards CE conformity, electromagnetic compatibility according to EN 61326, according to EMC Directive 2014/ 30/ EU Display Display with illumination, two line, cutout approx. 36 x15 mm (W x H), for displaying the Actual CO2 content and for setting the switchpoint |