|
|
AERASGARD® KFTM-LQ-CO2-WPatented quality product (patent no. DE 10 2014 010 719.1)
![]()
收藏
产品编号 1501-8118-7301-500
Voltage supply 24 V AC/ DC (± 10 %) Power consumption < 4.8 W/ 24 V DC typical; < 6.8 VA/ 24 V AC typical; peak current 200 mA Measuring range, humidity 0...100 % RH Operating range, humidity 0...95 % r. H. (without dew formation) Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % Output, humidity 0 -10 V or 4...20 mA (selectable via DIP switches) Measuring range, temperature –35...+80 °C Operating range, temperature –10...+60 °C Temperature deviation typically ± 0.2 K at +25 °C Output, temperature 0 -10 V or 4...20 mA (selectable via DIP switches) Sensor, VOC VOC sensor (metal oxide) with automatic calibration (VOC = volatile organic compounds) Measuring range, VOC 0...100 % air quality; referred to calibrating gas; multi-range switching (selectable via DIP switches) VOC sensitivity low, medium, high Output, VOC 0 -10 V (0 V = clean air, 10 V = polluted air) or 4...20 mA (selectable via DIP switches, switchpoint can be adjusted from 0...100 % of the output signal) Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas) Service life > 60 months (under normal load conditions) depending on the type of loading and gas concentration Measuring range, CO2 multi-range switching (selectable via DIP switches) 0...2000 ppm; 0...5000 ppm Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology) including atmospheric pressure compensation (up to 1100 mbar) with automatic and manual calibration Output, CO2 0 -10 V or 4...20 mA (selectable via DIP switches) Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C (whichever is higher) Pressure dependence ± 0,13 %/ mm Hg Gas exchange by diffusion Relay output with potential-free changeover contact 24 V (assignment selectable via DIP switches) Response time < 2 minutes Output 0 -10 V or 4...20 mA, working resistance < 800 Ω (selectable via DIP switches, selected variant applies for all outputs), with offset potentiometer (± 10 % of the measuring range) Sensor protection plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable (optional metal sinter filter, Ø 16 mm, L = 32 mm) Ambient temperature –10...+60 °C Process connection by mounting flange, plastic (included in the scope of delivery) Protective tube PLEUROFORM, material polyamide (PA6), with torsion protection, Ø 20 mm, vmax = 30 m/s (air) without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm) Electrical connection 0.14 - 1.5 mm2 via terminal screws Cable connection cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or M12 connector according to DIN EN 61076-2-101 (optional on request) Housing plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced, with quick-locking screws (slotted/ Phillips head - combination), colour traffic white (similar to RAL 9016) Housing dimensions 126 x 90 x 50 mm (Tyr 2) Cable gland M 16 x 1.5; including strain relief, exchangeable Long-term stability < 2 % in 15 years Protection class III (according to EN 60 730) Protection type IP 65 (according to EN 60 529) housing only! (PLEUROFORM IP 30) Standards CE conformity, electromagnetic compatibility according to EN 61326, according to EMC Directive 2014/ 30/ EU |