AERASGARD® KLQ-CO2 - Modbus(LCD)Patented quality product (patent no. DE 10 2014 010 719.1)The maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion level) and KCO2/ KLQ - CO2/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impactresistant plastic housing with quick-locking screws, plastic sinter filter (replaceable), incl. mounting flange, optionally with/without display, for determining the CO2-content of the air (0...5000 ppm), of the air quality (0…100 % VOC), the temperature (–35...+80 °C) and the relative air humidity (0…100 % RH). International system of units SI (default) can be changed to imperial (via Modbus). The following parameters can be accessed via the Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric pressure. The sensor is used in offices, hotels, convention centres, apartments, shops, etc. for the purpose of evaluating the indoor climate. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. One sensor for every 30 m2 of space is recommended.
Collect
产品编号 1501-8111-6071-500/1501-8111-6
Voltage supply 24 V AC/ DC (± 10 %) Power consumption < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical; peak current 200 mA Data points temperature, relative humidity, air quality (VOC), carbon dioxide (CO2), atmospheric pressure Sensor, VOC VOC sensor (metal oxide) with automatic calibration (VOC = volatile organic compounds) Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas) Measuring range, VOC 0...100 % air quality; referred to calibrating gas; multi-range switching (selectable via DIP switches) VOC sensitivity low, medium, high Measuring range, CO2 0...5000 ppm Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value Service life > 60 months (under normal load conditions) depending on the type of loading and gas concentration Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C (whichever is higher) Pressure dependence ± 0,13 %/ mm Hg Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology) including atmospheric pressure compensation (up to 1100 mbar) with automatic and manual calibration Gas exchange by diffusion Response time < 2 minutes Ambient temperature –10...+60 °C Bus protocol Modbus (RTU mode), address range 0...247 selectable Signal filtering 4 s / 32 s Process connection by mounting flange, plastic (included in the scope of delivery) Electrical connection 0.14 - 1.5 mm2, via push-in terminal Housing dimensions 126 x 90 x 50 mm (Tyr 2) Cable gland 2x M 16 x 1.5; including strain relief, exchangeable Long-term stability < 2 % in 15 years Protective tube PLEUROFORM, material polyamide (PA6), with torsion protection, Ø 20 mm, vmax = 30 m/s (air) without filter: NL = 202.5 mm / with plastic filter: NL = 235 mm (optional with metal filter: NL = 227 mm) Protection class III (according to EN 60 730) Protection type IP 65 (according to EN 60 529) housing only! (PLEUROFORM IP 30) Cable connection cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or M12 connector according to DIN EN 61076-2-101 (optional on request) Standards Housing plastic, UV-stabilised, material polyamide, 30 % glass-globe reinforced, with quick-locking screws (slotted/ Phillips head - combination), colour traffic white (similar to RAL 9016), housing cover for display is transparent ! Display three-line display with illumination, cutout approx. 70 x 40 mm (W x H), for displaying actual humidity, actual temperature, air quality and / or the actual CO2 content |