AERASGARD® RFTM-LQ-CO2-Modbus (LCD)Multifunctional indoor climate sensor AERASGARD® RFTM - LQ - PS - CO2 - Modbus (maximum expansion level) with Modbus connection, in an elegant plastic housing with snap-on lid, base with 4-hole attachment, optionally with / without display, type variant RFTM - CO2 - Modbus optionally with / without setpoint potentiometer. The room sensor is used for detecting the air humidity (0…100 % RH), room temperature (0...+50 °C), air quality (VOC) (0…100 %), the fine dust (PM) (0...1000 μg/m3) and CO2 content (0...5000 ppm) as well as a room control unit (% setpoint). International system of units SI (default) can be changed to imperial (via Modbus). The following parameters can be accessed via the Modbus: Temperature, relative humidity, air quality (VOC), fine dust (PM) and carbon dioxide (CO2). Use just one device to monitor and control the entire indoor climate effectively. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. It is used in offices, hotels, convention centres, apartments, shops, etc. One sensor for every 30 m2 of room area is recommended.
Collect
产品编号 1501-61B8-6021-500/1501-61B8-6
Voltage supply 24 V AC/ DC (± 10 %) Power consumption < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical; peak current 200 mA Data points temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) Operating range, humidity 0...95 % r. H. (without dew formation) Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % Operating range, temperature 0...+50 °C Temperature deviation typically ± 0.2 K at +25 °C Sensor, VOC VOC sensor (metal oxide) with automatic calibration (VOC = volatile organic compounds) Measuring range, VOC 0...100 % air quality; referred to calibrating gas; multi-range switching (selectable via DIP switches) VOC sensitivity low, medium, high Measuring accuracy, VOC ± 20 % of final value (referred to calibrating gas) Service life > 60 months (under normal load conditions) depending on the type of loading and gas concentration Measuring range, CO2 0...5000 ppm Sensor, CO2 optical NDIR sensor (non-dispersive infra-red technology) with automatic and manual calibration Measuring accuracy, CO2 typically ± 30 ppm ± 3 % of measured value Temperature dependence, CO2 ± 5 ppm/ °C or ± 0.5 % of measured value/ °C (whichever is higher) Pressure dependence ± 0,13 %/ mm Hg Gas exchange by diffusion Warm up time approx. 1 hour Response time < 2 minutes Ambient temperature 0...+50 °C Bus protocol Modbus (RTU mode), address range 0...247 selectable Signal filtering 4 s / 32 s Electrical connection 0.14 - 1.5 mm2, via push-in terminal Housing plastic, material ABS, colour pure white (similar to RAL 9010) Dimensions 98 x 98 x 33 mm (Baldur 2) Installation wall mounting or on in-wall flush box, Ø 55 mm, base with 4 holes, for attachment to vertically or horizontally installed in-wall flush boxes for rear cable entry, with predetermined breaking point for cable entry from top/ bottom in case of plain on-wall installation Long-term stability < 2 % in 15 years Protection class III (according to EN 60 730) Protection type IP 30 (according to EN 60 529) Standards CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014/ 30/ EU, Low Voltage Directive 2014/ 35/ EU |