AERASGARD® RFTM-PS-Modbus( LCD)Multifunctional indoor climate sensor AERASGARD® RFTM - LQ - PS - CO2 - Modbus (maximum expansion level) with Modbus connection, in an elegant plastic housing with snap-on lid, base with 4-hole attachment, optionally with / without display, type variant RFTM - CO2 - Modbus optionally with / without setpoint potentiometer. The room sensor is used for detecting the air humidity (0…100 % RH), room temperature (0...+50 °C), air quality (VOC) (0…100 %), the fine dust (PM) (0...1000 μg/m3) and CO2 content (0...5000 ppm) as well as a room control unit (% setpoint). International system of units SI (default) can be changed to imperial (via Modbus). The following parameters can be accessed via the Modbus: Temperature, relative humidity, air quality (VOC), fine dust (PM) and carbon dioxide (CO2). Use just one device to monitor and control the entire indoor climate effectively. This enables energy-saving room ventilation on an as-needed basis, thereby reducing operating costs and improving well-being. It is used in offices, hotels, convention centres, apartments, shops, etc. One sensor for every 30 m2 of room area is recommended.
Collect
产品编号 1501-2116-6021-200/1501-2116-6
Measuring range (PM) 0... 50 g/m3 0...100 g/m3 0...300 g/m3 0...500 g/m3 Measuring accuracy (PM) typically ± 10 g/m3 (± 10 % of measured value) at PM 2.5 typically ± 25 g/m3 (± 25 % of measured value) at PM 10 Particle size (PM) PM 2,5 (0,3...2,5 m); PM 10 (0,3...10 m) Voltage supply 24 V AC/ DC (± 10 %) Power consumption < 4.4 W/ 24 V DC typical; < 6.4 VA/ 24 V AC typical; peak current 200 mA Data points temperature, relative humidity, fine dust (PM) Operating range, humidity 0...95 % r. H. (without dew formation) Deviation of humidity typical ± 2 % r. H. (20…80 % r. H. ); at + 25 °C, otherwise ± 3 % Operating range, temperature 0...+50 °C Temperature deviation typically ± 0.2 K at +25 °C Ambient conditions 0...+50 °C Service life > 60 months (under normal load conditions) depending on the type of loading and gas concentration Warm up time approx. 1 hour Response time < 2 minutes Bus protocol Modbus (RTU mode), address range 0...247 selectable Signal filtering 4 s / 32 s Electrical connection 0.14 - 1.5 mm2 via terminal screws Housing plastic, material ABS, colour pure white (similar to RAL 9010) Dimensions 98 x 98 x 33 mm (Baldur 2) Long-term stability < 2 % in 15 years Protection class III (according to EN 60 730) Protection type IP 30 (according to EN 60 529) Installation wall mounting or on in-wall flush box, Ø 55 mm, base with 4 holes, for attachment to vertically or horizontally installed in-wall flush boxes for rear cable entry, with predetermined breaking point for cable entry from top/ bottom in case of plain on-wall installation Standards CE conformity, electromagnetic compatibility according to EN 61 326, EMC Directive 2014/ 30/ EU, Low Voltage Directive 2014/ 35/ EU Display display with illumination, two line, cutout approx. 36 x 15 mm (W x H), for displaying actual humidity, actual temperature, air quality and / or the actual CO2 content |