PREMASREG® DS-106/ DS-205 FThe mechanical PREMASREG® DS 1 differential pressure switch/monitor with metal bracket serves to monitor above-atmospheric, differential and below-atmospheric pressure of clean air as well as gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It is used as a flow monitor, differential pressure governor, pressure controller for flow monitoring at electric heating registers or for monitoring V-belts and filters. Further applications are found in air pressure deficiency protection, fan or air damper monitoring and limit value control. The switchpoint can be adjusted by means of an internal precision scale. The PREMASREG® DS-2 mechanical differential pressure switch/monitor with 4-hole plastic base ring is used for monitoring above-atmospheric, differential and below-atmospheric pressure of clean air, gaseous, non-aggressive media in air ducts, air intake or exhaust devices. It can serve as a flow monitor, differential pressure governor, pressure controller for flow monitoring of electric heating registers as well as monitor for V-belts and filters, as an air pressure deficiency protection monitor for ventilators, dampers, or as a limit value controller. Switchpoint adjustment is done using an internal precision scale. The device is factory-calibrated. These instruments are factory-calibrated. The DS 1 differential pressure sensor device is supplied including our ASD-06 connection set (2 m connection hose, two pressure connection nipples, screws). The DS-2 differential pressure sensor device is supplied including our ASD-06 connection set (2 m connection hose, two pressure connection nipples, screws).
Collect
产品编号 1302-4011/1302-4026
Mounting with mounting ring Pressure range high adjustment accuracy due to individual laser-etched scale for each switch Switching capacity (Contact load) 5 (0.8) A, 250 V AC 4 (0.7) A, 30 V DC Contact single-pole potential-free changeover contact, multi-layer contact, gold-plated (DDC compatible) Media temperature –30 ...+85 °C Pressure connection P1 (+) for higher pressure P2 (–) for lower pressure Ø 6.2 mm (nipples) Electrical connection 0.14 - 1.5 mm2, via terminal screws on circuit board Housing base: material PC (10 % GF), colour light grey (similar to RAL 7035), snap-on lid: material PC, transparent, cable gland PG 11 with strain relief Membrane silicone, LSR (Liquid Silicon Rubber, tempered at +200 °C, non-outgassing, LABS-free, no emission of varnish-adhesion inhibiting substances), long-term stability of switching points due to trapezoidal bead membranes Humidity < 90 % r. H., non-precipitating air Mounting by 4-hole base ring, plastic (included in the scope of delivery), recommended mounting position: vertical (pressure connections downward) – factory setting, horizontal (cap up/ down) Protection class II (according to EN 60 730) Protection type IP 54 with top cover (according to EN 60529) Standards CE conformity, low-voltage directive 2014/ 35/ EU Tests DVGW (according to DIN 1854), VDE 0630, EN 61058, directive on gas devices 2009/ 142/ EU, CE 0085 A P 0918 Function Contact 1 - 2 breaks when pressure/ differential pressure rises to the preset value. Contact 1 - 3 closes when pressure/ differential pressure drops and can be used as signal contact. Tests DVGW (nach DIN 1854) VDE 0630, EN 61058 Gasgeräterichtlinie 90 / 396 / EWG, CE 0085 A P 0918 |