THERMASGARD® HFTM - Modbus- T3Calibratable sleeve temperature measuring transducer THERMASGARD® HFTM - Modbus - T3, with Modbus connection, in an impact-resistant plastic housing with quick-locking screws, cable sensor with a stainless steel sleeve, optionally with/ without display, measures temperature (–50...+150 °C). International system of units SI (default) can be changed to imperial (via Modbus). The sleeve sensor is used to detect the temperature in liquid and gaseous media. It is used as a duct sensor or, if installed in immersion sleeve THE (accessories), as an immersion and screw-in sensor in liquids. Innovative Modbus sensor with galvanically separated RS485 Modbus interface, selectable bus termination resistance, DIP switch for setting the bus parameters and bus address in current-free state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, with customised programming in the 7-segment range and dot-matrix range). Uses internal diagnostics to detect sensor breakage or sensor short circuit as errors. The error messages can be retrieved via Modbus and are shown on the display. The sensor is factory-calibrated; an environmental precision adjustment by an expert is possible.
Collect
产品编号 1101-62A6
Voltage supply 24 V AC (± 20 %) and 15…36 V DC Power consumption < 1.2 W/ 24 V DC; < 1.8 VA/ 24 V AC Temperature deviation typically ± 0.2 K at +25 °C Sensor Pt1000, DIN EN 60751, class B (Perfect Sensor Protection) Measuring range –50...+150 °C Zero point offset ± 10 °C Ambient temperature Measuring transducer –30...+70 °C Medium clean air and non-aggressive, non-combustible gases Error detection sensor breakage, sensor short circuit Bus protocol Modbus (RTU mode), address range 0...247 selectable Signal filtering 0,3 s / 1 s / 10 s Sensor protection stainless steel, 1.4571, V 4A, Ø = 6 mm HTF 50 NL = 50 mm (other optional dimensions also available, NL = 30...400 mm) cable entry stamped (optional rolled) Electrical connection 0.2 - 1.5 mm², via push-in terminal Cable connection cable gland, plastic (2x M 20 x 1.5; with strain relief, exchangeable, inner diameter 8 - 13 mm) or M12 connector according to DIN EN 61076-2-101 (optional on request) Cable gland 2x M 20 x 1.5; with strain relief, exchangeable, inner diameter 8 - 13 mm sensor cable Silicone, SiHF, 2 x 0,25 mm²; cable length (KL) = 1.5m (other lengths and jacket materials, e.g. PTFE or glass fibre with steel mesh, available on request) Permissible air humidity < 95 % RH, non-precipitating air Protection class III (according to EN 60 730) Protection type IP 65 (according to EN 60 529) sleeve humidity-tight (standard) IP 68 (according to EN 60 529) sleeve water-tight (optional) IP 54 (according to EN 60 529) housing / with glass fibre cable (optional) Standards CE conformity, electromagnetic compatibility according to EN 61326, according to EMC Directive 2014/ 30/ EU Internal diagnostics Error 1 at sensor breakage Error 2 at sensor short circuit |