Calibratable HYGRASGARD® KFF - SD / KFTF - SD duct humidity/temperature transmitters (± 2,0%), with plastic sinter filter (metal sinter filter optional), housing made of impact resistant plastic with snap-on cover, with cable gland (or optional M12 connector according to DIN EN 61076-2-101).

Calibratable HYGRASGARD® KFF / KFTF or KFF - 20 / KFTF - 20 duct humidity/temperature transmitters (±2,0% or ±1,8%, respectively) with plastic sinter filter (metal sinter filter optional), housing made of impact resistant plastic with quick-locking screws, optionally with/without display, with cable gland (or optional M12 connector according to DIN EN 61076-2-101).
The sensor devices measure relative humidity and/or air temperature and convert the measurands into a standard signal of 0-10 V or 4...20 mA. They support four switchable temperature ranges and are applied in non-aggressive dust-free atmospheres in refrigeration, air conditioning, ventilation and cleanroom engineering. These measuring transducers provide precise detection of humidity. A digital long-term stable sensor is used as measuring element for humidity. The sensor is factory-calibrated and can be fine-tuned to ambient conditions by an expert.


No price
Measured variables
output
Display
  1. Yes
  2. No
output model
Collect
产品编号 1201-8112/1201-3112
  • TECHNICAL DETAILS
  • DOWNLOADS
Voltage supply
15...36 V DC
depending on working resistance, residual ripple stabilised ± 0.3 V
Power consumption
< 1.1 VA/ 24 V DC ; < 2.2 VA/ 24 V AC
Working resistance
Ra (ohm) = (Ub -14 V)/ 0.02 A for I variant
Measuring range, humidity
0...100 % r. H.
(output corresponding to 4...20 mA)
Deviation of humidity
typical ± 1.8 % r. H. (10…90 % r. H. ); at + 25 °C, otherwise ± 2,0 % r. H.
Output, humidity
4...20 mA
Sensor protection
plastic sinter filter, Ø 16 mm, L = 35 mm, exchangeable
(optional metal sinter filter, Ø 16 mm, L = 32 mm)
Process connection
by mounting flange, plastic
(included in the scope of delivery)
Protective tube
PLEUROFORM, material polyamide (PA6), with torsion protection,
Ø 20 mm, NL = 235 mm (optionally 100 mm), vmax = 30 m/s (air)
(option on request in stainless steel V2A (1.4301), Ø 16mm)
Electrical connection
2-, 3- or 4-wire connection
0.14 -1.5 mm ² via terminal screws on circuit board
Cable connection
cable gland, plastic (M 16 x 1.5; with strain relief, exchangeable, max. inner diameter 10.4 mm) or
M12 connector according to DIN EN 61076-2-101 (optional on request)
Housing
plastic, UV-stabilised,
material polyamide, 30 % glass-globe reinforced,
with quick-locking screws
(slotted/ Phillips head - combination),
colour traffic white (similar to RAL 9016),
housing cover for display is transparent !
Housing dimensions
126 x 90 x 50 mm (Tyr 2)
Cable gland
M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Long-term stability
± 1 % per year
Permissible air humidity
< 95 % RH, non-precipitating air
Protection class
III (according to EN 60 730)
Protection type
IP 65 (according to EN 60 529)*
Standards
CE conformity,
according to EMC directive 2014/ 30/ EU,
according to EN 61326-1, according to EN 61326-2-3
Display
three-line display with illumination, cutout 70 x 40 mm (W x H),
for displaying ACTUAL temperature and/ or ACTUAL humidity